| Image |
Price |
Product+ |
Manufacturer |
| $19.95 | | |
This is a download of the installation manual for the high-end Westec 5000 fire / security alarm control panel and the Westec 4000(5000s) fire / security alarm control panel. The Westec 4000 (5000s) was made by Ademco.
Scanned for viruses, clean download 8.39 MB Spend days or weeks looking for it or download this installation manual here in high quality PDF format at a low price. |
| $7.95 | | |
The Apex Advantage is a high end alarm control panel. This download is a PDF of the 38 page installation manual. The Apex Adavatage is capable of both hardwire and wireless supervision ( with optional SR-201 receiver. The Apex Advantage has 16 on board supervised burglary zones and 1 ( 2 Wire Fire zone ). This installation manual contains detailed step by step information on how to enter program the Apex Advantage alarm control panel. Your will be paying for the bandwidth necessary to download the Apex Advantage Control panel installation manual. |
| $19.95 | | |
This is a PDF download of a very hard to find manual for the Commander 2000 also known by ADT customers as the RF18.
ITI was bought by GE Security and this panel is no longer being made or supported. The download is in PDF format. Spend days or weeks looking for it or download it here in high quality PDF format. |
| $7.95 | | |

8 - 32 Hybrid Zone Control Panel - GEM-P1632
Seamlessly supports all Gemini wireless transmitters using standard receivers
The Gemini™ GEM-P1632 Hybrid 8 to 32-Zone Control/Communicator features 8 zones expandable to 32 zones with (multiplexing) assignable to either of two areas. Supporting up to 32 user codes, 8 relays, and X-10 support,
the GEM-P1632 powerhouse has it all, wireless or hardwire! The panel supports all reliable, crystal-control Gemini Wireless, proven in independent tests to outperform the top competitive brands.
• 8 Hardwire/Wireless Zones on Board.
• Up to 32 zones with multiplex expansion including 2 2-wire fire zones (7;8)
• Uses economy GEMEZM4/8 Zone Expansion Module (or standard GEMEZM8).
• “Self-Programming Plus 2” menu-driven self-programming mode with either custom alpha keypad, GEMRP1CAe2 or KA1CA (with Stay and Away keys).
• Fuseless maintenance-free operation
• Up to 32 user codes.
• Up to 2 areas; partitionable by area.
• 3 on-board outputs, up to16 external relay outputs (RM3008s).
• Up to 2 RF receivers
• Interior bypass group with programmable automatic interior bypass.
• Up to 8 X-10 devices supported for 16 different events.
• 255 event schedule.
• 400 event log.
• Auto Arm.
• Uses up to 7 of any of the Classic or K-Series Stay & Away keypads: custom
alpha/icon or digital keypads (as shown on right).
• Programmable Telco line cut supervision with delay.
• 3 keypad panic (F, P, A)
• Major communicator formats, including: 4/2, SIA, 4+2 and Point ID, plus pager.
• Backup/double/split reporting; three 20-digit telephone numbers.
• Dynamic battery test.
• Reports alarms, restores and troubles by zone.
• 2 programmable entry delay times.
• Chime by zone.
• 8 EOL burglary zones programmable for area, E/E delay, interior, follower, day zone, chime, fire options, sensor watch, swinger shutdown, cross zoning
, etc.
• Multiplex Expandability with GEMEZM4/8 or GEMEZM8 zone expansion modules
• Quickloader up/downloading, including unique unattended method
• Choice of 8 or 16 pt Gemini RF receivers or keypad/receiver
• Event log with open/close suppression
• Supports Wizard™ IIe Talking Phone-In interface module
Output power amps: (with 20VA transformer included) 500mA/2A; with optional 40VA trans 650mA/2A.
Operating temp: 0 - 49 degrees C.
Input power: 16.5VAC via Class 2 plug-in 40VA transformer
Loop voltage: 10-13Vdc
Loop current: 2.5mA with 2.2k ohm EOLR; 5mA for 2-wire fire
Loop resist.: 300 ohm max.; 50 ohm max for 2-wire fire
Aux & remote power: 12Vdc regulated
Combined standby current: 650mA
Alarm current: 2A
Burg. voltage output: 1; Programmable negative outputs: 2
UL Listed. CPO1 compliant models available.
|
| $49.95 | | |
This is a very rare set of Westec alarm service / install manuals.
You may not find this complete set anywhere else on the net.
Includes the following Westec panels in CAB format (Reader Included) :
100, 152, 252(1131), 400, 500, 1153, 1164, 701CE( 2000A ), 702CE( 2000B ), 703CE, 720CE, 752, 760, 766, 800, 800B, 842, 900/901, HG-24, MS4000( 5000S ), 3000, 5000
These are full manuals and are printable.
It is a large download 70.9 MB expanding to 300MB in ZIP format.
Common Search Terms:
westec alarm, westec alarms, westec control, westec panel manual, westec 5000s, westec alarm instructions, westec service manual |
| $7.95 | | |
Very rare Installation Manual for an Optex MDC-16.
Spend days or weeks looking for it or download it here in high quality PDF format at a low price. |
| $7.95 | | |
SXV Installation Manual. Very hard to find.
Spend days or weeks looking for it or download it here in high quality PDF format at a low price. |
| $7.95 | | |
Ademco V20p (Safewatch 3000) Installers Manual.
Spend days or weeks looking for it or download it here in high quality PDF format at a low price. |
| $7.95 | | |
Installation manual for the Ademco Vista 100 Alarm System / Control Panel.
Full manual 222 pages
Spend days or weeks looking for it or download it here in high quality PDF format at a low price. |
| $7.95 | | |
Installation / Programming and Operation manual for a Moose Z-1100 Alarm System / Control Panel. System 1.
11 Zone Security Control Communicator. Hard to find manual.
Spend days or weeks looking for it or download it here in high quality PDF format at a low price. |
| $7.95 | | |
Z1100 System 2 Installation manual. 11 zone security control communicator.
Includes the users manual.
53 pages Spend days or weeks looking for it or download it here in high quality PDF format at a low price. |